Link to manual will be sent on Your email address after You place order.This product was added to our catalog on Monday 07 May, 2007.Product ReviewsThere are currently no reviews for this product.Other reviewsVery nice clear manual with specifications, exploded views and schematics, been searching for one of these for years. Thanks.Very nice site and the manual is great. A life-saver. Thank you so much!Contains mechanism diagrams, parts lists and schematics for all worldwide versions of DC-X88Z.
Also includes remote schematic etc. A few non-essential pages are missing such as specifications.Includes the mechanical and electronic calibration instructions for the tape decks.Excellent service.
Service manuel conforme.C'est parfait. Merci!Super fast!Excellent quality and solid transaction!I will return.ThanksCustomers who bought this product also purchasedShopping Cart0 itemsLog InE-Mail Address:Password:ReviewsPaymentsInformationWhat's New?$4.99.
Measurement Priority Measurements made by internal maternal parameters (SpO2, NIPB, and MHR) take precedence above the same measurements made by an externally connected device. The MHR measurement obtained from the SpO2 measurement has higher priority than the MHR obtained from the NIBP measurement.
Connecting External Devices 2. Only if this parameter is installed on the external device. The supported external devices are connected to the monitor via the Dual Serial interface at the rear of the monitor. External devices connected to socket 1 that can monitor SpO 2 have priority over the Nellcor OxiFirst Oxygen Saturation monitor (N-200). Warning Before connecting an external device to the monitor, connect the equipotential grounding point (3) to earth potential. Use the grounding cable supplied with the monitor.
The power cord of the external device must be plugged into a wall-mounted power outlet - not into an extension block. The Dual Serial Interface has two sockets: see Figure 5-1. Use socket 1 (9 pin) for connecting: Philips M1165A/1166A/1175A/1176A CMS, all models Philips 78352C/78354C Compact Configurable Monitor.
Dinamap 1846/8100 NIBP Monitor. COLIN Press-Mate/Nippon Colin Listmini Model BP-8800. Datascope Accutor 3, 4, 3SAT and 4SAT. Use socket 2 (25 pin) for connecting: Nellcor Maternal Oxygen Saturation monitor (N-200) and Nellcor OxiFirst Fetal Oxygen Saturation monitor (N-400). 56 System InterfacesPhilips CMS, Philips 78352C/ 78354C, Dinamap 1846/ 8100, Datascope Accutorr Monitor COLIN BP- 8800 To connect either a Philips CMS, a Philips 78352C or 78354C, a Dinamap 1846/8100, or a Datascope Accutorr monitor follow the instructions below. The screws for the Philips CMS and Philips 78352C or 78354C are metric and should be tightened by hand only, and not with a screwdriver.
Use interface cable M1350-61609. Connect the 9-pin end of the cable to the Philips Series 50 XM or XMO monitor. Connect the 25-pin end of the cable to the external device. Secure the interface cable by the screws at the cable connectors. Figure 5-9 Interface Cable M1350-61609 To connect a COLIN BP-8800 Monitor to a Philips Series 50 XM or XMO monitor: Use the interface cable supplied by the COLIN Corporation with the NIBP monitor. Connect the 9-pin end of the cable to the Philips Series 50 XM or XMO monitor. Connect the 15-pin end of the cable to the COLIN.
Secure the interface cable by the screws at the cable connectors. Figure 5-10 COLIN Interface Cable System Interfaces 57. Page 1 and 2:Obstetrical Care FETAL MONITORING S. Page 3 and 4:Series 50 Fetal Monitors Series 50.